voigt error... followup

From: <rgibson_at_email.domain.hidden>
Date: Fri, 16 Nov 2007 13:50:50 -0500
I think I found the problem.  The voigt.vtherm parameter goes negative during
the fits (because I allowed for a minimum value < 0 in set_par).  I think it
wasn't obvious because fit_counts would crash before updating the vtherm
parameter when it went negative.

Suggest robustifying voigt.vtherm and voigt.fwhm to not halt ISIS if evaluated
when negative?

Thanks,
Rob

----
You received this message because you are
subscribed to the isis-users list.
To unsubscribe, send a message to
isis-users-request_at_email.domain.hiddenwith the first line of the message as:
unsubscribe
Received on Fri Nov 16 2007 - 13:50:58 EST